Researchers Seek Better Neural Control of Prosthetics for Amputees

Sandia National Laboratories researchers, using off-the-shelf equipment in a chemistry lab, have been working on ways to improve amputees’ control over prosthetics with direct help from their own nervous systems.

Organic materials chemist Shawn Dirk, robotics engineer Steve Buerger and others are creating biocompatible interface scaffolds. The goal is improved prosthetics with flexible nerve-to-nerve or nerve-to-muscle interfaces through which transected nerves can grow, putting small groups of nerve fibers in close contact to electrode sites connected to separate, implanted electronics.

Neural interfaces operate where the nervous system and an artificial device intersect. Interfaces can monitor nerve signals or provide inputs that let amputees control prosthetic devices by direct neural signals, the same way they would control parts of their own bodies.

Sandia’s research focuses on biomaterials and peripheral nerves at the interface site. The idea is to match material properties to nerve fibers with flexible, conductive materials that are biocompatible so they can integrate with nerve bundles.

“There are a lot of knobs we can turn to get the material properties to match those of the nerves,” Dirk said.

Buerger added, “If we can get the right material properties, we could create a healthy, long-lasting interface that will allow an amputee to control a robotic limb using their own nervous system for years, or even decades, without repeat surgeries.”

Researchers are looking at flexible conducting electrode materials using thin evaporated metal or patterned multiwalled carbon nanotubes.

The work is in its early stages and it might be years before such materials reach the market. Studies must confirm they function as needed, then they would face a lengthy Food and Drug Administration approval process.

But the need is there. The Amputee Coalition estimates 2 million people in the United States are living with limb loss. The Congressional Research Service reports more than 1,600 amputations involving U.S. troops between 2001 and 2010, more than 1,400 of those associated with the fighting in Iraq and Afghanistan. Most were major limb amputations.

Before joining Sandia, Buerger worked with a research group at MIT developing biomedical robots, including prosthetics. Sandia’s robotics group was developing prosthetics before his arrival as part of U.S. Department of Energy-sponsored humanitarian programs to reduce proliferation risks.

Robotics approached the problem from a technical point of view, looking at improving implantable and wearable neural interface electronics. However, Buerger said that didn’t address the central issue of interfacing with nerves, so researchers turned to Dirk’s team.

“This goes after the crux of the problem,” he said.

The challenges are numerous. Interfaces must be structured so nerve fibers can grow through. They must be mechanically compatible so they don’t harm the nervous system or surrounding tissues, and biocompatible to integrate with tissue and promote nerve fiber growth. They also must incorporate conductivity to allow electrode sites to connect with external circuitry, and electrical properties must be tuned to transmit neural signals.

Dirk presented a paper on potential neural interface materials at the winter meeting of the Materials Research Society, describing Sandia’s work in collaboration with the University of New Mexico and MD Anderson Cancer Center in Houston. Co-authors are Buerger, UNM assistant professor Elizabeth Hedberg-Dirk, UNM graduate student and Sandia contractor Kirsten Cicotte, and MD Anderson’s Patrick Lin and Gregory Reece.

The researchers began with a technique first patented in 1902 called electrospinning, which produces nonwoven fiber mats by applying a high-voltage field between the tip of a syringe filled with a polymer solution and a collection mat. Tip diameter and solution viscosity control fiber size.

Collaborating with UNM’s Center for Biomedical Engineering and department of chemical engineering, Sandia researchers worked with polymers that are liquid at room temperature. Electrospinning these liquid polymers does not result in fiber formation, and the results are sort of like water pooling on a flat surface. To remedy the lack of fiber formation, they electrospun the material onto a heated plate, initiating a chemical reaction to crosslink the polymer fibers as they were formed, Dirk said.

Researchers were able to tune the conductivity of the final composite with the addition of multiwalled carbon nanotubes.

The team electrospun scaffolds with two types of material — PBF, or poly(butylene fumarate), a polymer developed at UNM and Sandia for tissue engineering, and PDMS, or poly(dimethylsiloxane). PBF is a biocompatible material that’s biodegradable so the porous scaffold would disintegrate, leaving the contacts behind. PDMS is a biocompatible caulk-like material that is not biodegradable, meaning the scaffold would remain. Electrodes on one side of the materials made them conductive.

Sandia’s work was funded through a late-start Laboratory Directed Research & Development (LDRD) project in 2010; afterward the researchers partnered with MD Anderson for implant tests. Sandia and MD Anderson are seeking funding to continue the project, Dirk said.

Buerger said they’re using their proof-of-concept work to obtain third-party funding “so we can bring this technology closer to something that will help our wounded warriors, amputees and victims of peripheral nerve injury.”

Sandia and UNM have applied for a patent on the scaffold technique. Sandia also filed two separate provisional patent applications, one in partnership with MD Anderson and the other with UNM, and the partners expect to submit full applications this year.

The MD Anderson collaboration came about because then-Sandia employee Dick Fate, an MD Anderson patient who’d lost his left leg to cancer, thought the hospital and the Labs were a natural match. He brokered an invitation from Sandia to the hospital, which led to the eventual partnership.

Fate, who retired in 2010, views the debilitating effect of rising health care costs on the nation’s economy as a national security issue.

“To me it seems like such a logical match, the best engineering lab in the country working with the best medical research institution in the country to solve some of these big problems that are nearly driving this country bankrupt,” he said.

After Sandia researchers came up with interface materials, MD Anderson surgeons sutured the scaffolds into legs of rats between a transected peroneal nerve. After three to four weeks, the interfaces were evaluated.

Samples fabricated from PBF turned out to be too thick and not porous enough for good nerve penetration through the scaffold, Dirk said. PDMS was more promising, with histology showing the nerve cells beginning to penetrate the scaffold. The thickness of the electrospun mats, about 100 microns, were appropriate, Dirk said, but weren’t porous enough and the pore pattern wasn’t controlled.

The team’s search for a different technique to create the porous substrates led to projection microstereolithography, developed at the University of Illinois Urbana-Champaign as an inexpensive classroom outreach tool. It couples a computer with a PowerPoint image to a projector whose lens is focused on a mirror that reflects into a beaker containing a solution.

Using a laptop and a projector, Dirk said the researchers initially tried using a mirror and a 3X magnifying glass, but abandoned that because it produced too much distortion. They now use the magnifying glass to focus UV light onto the PDMS-coated silicon wafer to form thin porous membranes.

While the lithography technique is not new, “we developed new materials that can be used as biocompatible photo crosslinkable polymers,” Dirk said.
The technique allowed the team to create a regular array of holes and to pattern holes as small as 79 microns. Now researchers are using other equipment to create more controlled features.

“It’s exciting because we’re getting the feature size down close to what is needed,” Buerger said.

httpv://www.youtube.com/watch?v=QlLV94B_R64
This video shows the microstereolithograph technique used by a Sandia National Laboratories’ team working on neural interfaces patterning a much larger structure than would be done for the research. In this case, the technique is patterning the Sandia thunderbird logo. Neuroscience video from SandiaLabs user on YouTube.com.

Notes about this neural prosthetics research article

Sandia National Laboratories is a multi-program laboratory operated by Sandia Corporation, a wholly owned subsidiary of Lockheed Martin company, for the U.S. Department of Energy’s National Nuclear Security Administration. With main facilities in Albuquerque, N.M., and Livermore, Calif., Sandia has major R&D responsibilities in national security, energy and environmental technologies, and economic competitiveness.

Contact: Sue Holmes – Sandia National Laboratory
Source: Sandia National Laboratory press release
Video Source: Neuroscience video made available by YouTube.com user SandiaLabs

Join our Newsletter
I agree to have my personal information transferred to AWeber for Neuroscience Newsletter ( more information )
Sign up to receive our recent neuroscience headlines and summaries sent to your email once a day, totally free.
We hate spam and only use your email to contact you about newsletters. You can cancel your subscription any time.